GE 8101-HI-TX-02

[Product characteristics]

① Brand: GE

② Model: 8101-HI-TX-02

③ Inventory quantity: 10

④ Color: new

⑤ Freight: according to different local freight forwarders, the freight in different regions shall prevail.

⑥ Include tariff or not: do not include any taxes

⑦ Packaging: use the Seller’s safe packaging

Category:
Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!

Description

8101-HI-TX-02
• 8 single-ended 4-20 mA input channels
• Non-incendive field circuits
• HART pass-through
• HART variable and status reporting
• 2- or 4-wire transmitters
• Open and short circuit detection
• 24 V dc bussed field power required
MODULE SPECIFICATION
See also System Specification
INPUTS
Number of channels
• 8, single-ended
Nominal signal range (span)
• 4 to 20 mA
Full signal range
• 1 to 23 mA
Line fault detection
• Short circuit current – > 23.5 mA
• Open circuit current – < 0.5 mA Output voltage (@ 20mA) •13.5 V (min.) Output current • 32 mA (max.) Accuracy (over temp range) • ± 0.1% of span Resolution • 16 bits Repeatability • 0.05% of span Isolation • Any channel to Railbus – 100 V ac • Between channels – None CONFIGURABLE PARAMETERS Alarms • High, high-high, low and low-low Alarm deadband (hysteresis) • User defined value Input filter time constant • User defined value Input dead zone • User defined value Drive on failsafe • Disabled / upscale / downscale Channel status • Active / Inactive HART variable and status reporting • Enable / Disable RESPONSE TIME Signal change to availability on Railbus • 4–20 mA mode – 27 ms (max.) • HART mode – 0.75 s per channel SAFETY FM non-incendive field wiring parameters (each channel) • Voc = 28.7 V; Isc = 33 mA; Ca = 0.17 μF; La = 11.0 mH POWER SUPPLIES Railbus (12V) current • 100 mA (typ.) • 150 mA (max.) Bussed Field Power • 2-wire Tx – 300 mA (max.) • (@ 24 V dc ±10%) 4-wire Tx – 60 mA (max.) MECHANICAL Module Key Code • A1 Module width • 42 mm Weight • 200 g 0de4a7deeec3d3ffbd29 GE 8101-HI-TX-02
a62ed471ac32396f703f GE 8101-HI-TX-02

45748d663401f7a75533 GE 8101-HI-TX-02

83b6a873b3fcb4efac80 GE 8101-HI-TX-02

3f7aaae534616a9260d9 GE 8101-HI-TX-02

Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).