HYDRAN M2
Enhanced DGA monitoring for transformers Transformers are key and expensive components of the electrical grid and knowledge of their health condition is essential to having a reliable network. When a transformer’s insulation system is overstressed, gases are produced that dissolve in the oil. Dissolved Gas-in-oil Analysis (DGA) is recognized as the best indicator of developing faults. Asset Supervision • Easy to permanently install on a single transformer oil valve. No extra piping or pump required. Optional inputs for other sensors The Hydran™ M2 is a continuous on-line dissolved gas and moisture in oil monitoring device that alerts personnel of developing fault conditions in their transformer. It provides key monitoring information and minimizes the risk of an unplanned outage. • Choice of gas sensor: “Hydrogen only” or “Composite gas” which responds 100% to Hydrogen (general fault gas) and is also sensitive to Carbon Monoxide (paper) Acetylene (arcing) and Ethylene (oil) Through the connection of additional sensors (for example top and bottom tank oil temperature, transformer load or ambient temperature), additional information can be captured and used to correlate with DGA and moisture values for a more in-depth analysis of the transformer’s condition. • Moisture sensor measures water in the oil, a result of insulating paper degradation (produces CO + water) or leaking gaskets This wealth of data can, not only be transmitted raw using the M2’s wide range of communication options but can also be converted into useful information through the on-board calculation of IEEE® standard’s based transformer mathematical models to provide further condition information. Configurable Alarms Key Benefits • Continually measures dissolved fault gases and moisture in oil for early identifications of potential issues before they become critical transformer failures • Choice of gas sensor: traditional “Composite gas” or more basic “Hydrogen only” • Built-in calculation of transformer models based on IEEE standard (for mineral oil only) • Wide range of communication options and protocols simplifying integration into SCADA or DCS • Third generation of this proven design, with very large global installed base • Supports new lower flammability ester based oils as well as mineral transformer insulation oils Applications Power Utilities • All-in-one solution for important medium size transformers • Focuses and prioritizes asset replacement strategy Industrial Plants • Reduces the risk of process interruption due to power failure • Minimizes costly production downtime • An alarm is raised when an abnormal level of fault gas or moisture is detected. Two alarm levels (one for Alert and one for Alarm) can be set to show increasing severity • Alarms can also be set on values from optional analogue input cards or from optional calculated transformer models • Automatic self-test every 15 days will trigger service alarm if it detects a fault, including power failure, oil valve closed, faulty sensor Mark III Improvements • Completely overhauled with improved sensor durability, new electronic boards and power supply to make it RoHS compliant while increasing device reliability and capabilities • Suitable for transformers using mineral insulating oil but now also ester based oils (natural or synthetic) • Compatibility with GE’s acclaimed Perception™ softwa
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!