HONEYWELL CC-TDIL01
Function
The Analog Input Module accepts high level current or voltage inputs from transmitters and sensing devices.
Notable Features
• Extensive self-diagnostics
• Optional redundancy
• Open Wire Detection
• Supplies non-incendive field power
• Non-incendive Power
• HART-capable, multivariable instruments and multiple
modems for fast collection of control variables
• Fast loop scan
• PV protection through an open wire detection
diagnostic
• Open-wire Bad PV Detection
Detail Specifications – Analog Input with HART
Parameter Specification
Input / Output Model CC-PAIH02 – High-Level Analog Input with HART
IOTA Models Non-Redundant Redundant
CC-TAIX01 CC-TAIX11
CC-GAIX21 CC-GAIX11
CC-TAID01 CC-TAID11
Input Type Voltage, current (2-wire or self-powered transmitters)
Input Channels 1 16 Channels (12 Single Ended / 4 Differential )
Common Mode Rejection Ratio, dc to 60 Hz (500
source imbalance)
70 dB
Common Mode Voltage, dc to 60 Hz -6 to +5 V peak
A/D Converter Resolution 16 bits
Input Range 1 0 to 5 V, 1 to 5 V, 0.4 to 2 V, 4-20 mA (through 250 Ω)
Normal Mode Rejection Ratio, at 60 Hz 19 dB
Parameter Specification
Normal Mode Filter Response Single-pole RC, -3 dB @ 6.5 Hz
Maximum Normal Mode Input (differential inputs, no
damage)
± 30 Volts
Crosstalk, dc to 60 Hz (channel-to-channel) -60 dB
Input Impedance (voltage inputs) > 10 M Ω powered
Input Scan Rate 50 ms
Hardware Accuracy (@ CMV = 0 V) ± 0.075% of full-scale (23.5°± 2°C)
± 0.15% of full-scale (0 to 60°C)
Transmitter Field Power Conditioning Individually Protected Current Limiting Circuits for Class 1,
Div 2 non-incendive interfacing. No fusing required
239-RTD-AN design principle
What does DSTC456 include
2500-C200 related processes
FBM224 features
MDSKSRS056-33 Advantages and disadvantages
T9110 effect
8V1090.00-2 B&R option
5501-470 Usage
FBMSVH usage
PRD-P303250Z-35 How to choose
How about 140MMS53502
DFS56L/TF/RH1M/KK processing method
PIB671-1500 installation features
2880045-01 Maintenance
870ITEC-AYFNZ market channel processing channel
MVME5100 precautions difference
PR6423/010-010-CN correct use method
SR469-P5-HI-A20 effect
UR9CH GE usage
DSDP170 standard
MTR-4-215 design principle
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!