VIBRO 200-560-000-113 VM600

¥888.00

VIBRO 200-560-000-113 VM600
Dynamic signal inputs
Filtering : Filtered for protection against electromagnetic interference
(conforms to EC standards).
Refer to the VM600 MPC4 machinery protection card data sheet
for further information.
Buffered dynamic signal outputs
Filtering : Filtered for protection against electromagnetic interference
(conforms to EC standards).
Refer to the VM600 MPC4 machinery protection card data sheet
for further information.
Speed/phase reference inputs
Filtering : Filtered for protection against electromagnetic interference
(conforms to EC standards).
Refer to the VM600 MPC4 machinery protection card data sheet
for further information.

Category:
Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!

Description

Vibro-Meter ®
VM600 IOC4T
input/output card
KEY FEATURES AND BENEFITS
• From the Vibro-Meter® product line
• Signal interface card with 4 dynamic signal
inputs and 2 tachometer (speed) inputs, for the
MPC4 machinery protection card
• Screw-terminal connectors (48 terminals) for all
input/output connections
• Contains 4 relays which can be attributed to
alarm signals, under software control
• 32 fully-programmable open-collector outputs
(jumper selectable) to IRC4 and RLC16 relay
cards
• Buffered “raw” sensor signals and analog
output signals (voltage or current) for vibration
channels
• EMI protection for all inputs and outputs
• Live insertion and removal of cards
(hot-swappable)
• Available in “standard” and “separate circuits”
versions
APPLICATIONS
• Machinery protection and/or basic
condition monitoring
c37588e2f33198f967fd VIBRO 200-560-000-113 VM600
DESCRIPTION
IOC4T card
The IOC4T input /output card acts as a signal
interface for the VM600 series MPC4 machinery
protection card, from Meggitt’s Vibro-Meter®
product line. It is installed in the rear of a VM600
rack and connects directly to the rack backplane
via two connectors.
Each IOC4T card is associated with a
corresponding MPC4 card and is mounted
directly behind it in the VM600 rack (ABE04x or
ABE056). The IOC4T operates in slave mode and
communicates with the MPC4, through
connector P2, using an Industry Pack (IP)
interface.
The front panel of the IOC4T (rear of the VM600
rack) contains terminal strip connectors for wiring
to the transmission cables coming from
measurement chains (sensors and /or signal
conditioners). The screw-terminal connectors are
also used to input all signals from and output all
signals to any external control system.
The IOC4T card protects all inputs and outputs
against electromagnetic interference (EMI) and
signal surges and also meets electromagnetic
compatibility (EMC) standards.
The IOC4T connects the raw dynamic (vibration)
and speed signals from the sensors to the MPC4.
These signals, once processed, are passed back
to the IOC4T and made available on the terminal
strip on its front panel (rear of VM600). For the
dynamic signals, four on-board digital-to-analog
converters (DACs) provide calibrated signal
outputs in the range 0 to 10 V. In addition, four onboard voltage-to-current converters allow the
signals to be provided as current outputs in the
range 4 to 20 mA (jumper selectable).
The IOC4T contains four local relays that can be
attributed to any specific alarm signals under
software control. For example, these may be used
to signal an MPC4 fault or a problem detected by
a common alarm (Sensor OK, Alarm and Danger)
in a typical application.
In addition, 32 digital signals representing alarms
are passed to the rack backplane and may be
used by optional RLC16 relay cards and / or IRC4
intelligent relay cards mounted in the rack
(jumper selectable).
Applications information
When used as a card pair with an MPC4
machinery protection card, the IOC4T is highly
suitable for machinery monitoring and protection
in a wide range of industrial applications.
For further information on the use of MPC4/IOC4T
card pairs in general, refer to the
VM600 machinery protection system (MPS)
hardware manual and the VM600 MPSx software
manuals. For information on the use of
MPC4/IOC4T card pairs in functional safety
contexts, refer to the refer to the VM600
functional safety manual.
For specific applications, contact your local
Meggitt representative.

Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!