Vibro-Meter 200-565-000-HHh IOC16T
VIBRATION AND ANALOG INPUTS
A/D converter : 1 converter per channel, 14 bits
Values transmitted to PC are truncated to 12 bits + sign
(resolution 1 in 4096)
Maximum sampling rate : 51.2 kHz
Accuracy
• AC measurement (voltage based) : 1% of input FSD
• DC measurement (voltage based) : 1% of input FSD
• DC measurement (current based) : 2% of input FSD, or 1% with externally mounted resistors
Input range (switch selected)
• AC measurement : 0.1, 0.2, 0.5, 1.0, 2.0, 4.0, 10.0, 20.0 V FSD
• DC measurement : 0 to +24 V FSD or -24 to 0 V FSD (fixed)
• DC thermocouple : 61.022 mV FSD
Maximum frequency span : 20 kHz
Minimum frequency : AC measurement with 0.16 Hz HP filter (at -3 dB)
DC bandwidth : DC measurement with 0.20 Hz LP filter (at -3 dB)
Anti-aliasing attenuation : 70 dB at f > 1.56 x fc
Signal / noise : > 70 dB up to 10 kHz
> 60 dB at 20 kHz
Crosstalk isolation : < -75 dB
Max. common mode voltage : 50 V for vibration/process inputs, 3 V for thermocouple inputs
BACKGROUND ACQUISITION MODE
Order tracking range (synchronous) : 15 RPM to 30,000 RPM
Order tracking span (synchronous) : 1.56, 3.125, 6.25. 12.5, 25, 50, 100, 200 and 400 orders
Fixed frequency span (asynchronous) : 0 to .1, .2, .5, 1, 2, 5, 10 and 20 kHz
FFT resolution : 400 lines
FFT window : Rectangular in order tracking mode
Hanning in fixed frequency mode
Real-time sampling rate : 2.56 x frequency or order span
Real-time waveform sent to host : 256 samples / revolution over 4 revolutions
Real-time spectra resolution : 12 bits
ALTERNATIVE ACQUISITION MODE (LOGGED ON SCHEDULE OR ALARM)
Order tracking span (synchronous) : 0 to 1.56, 3.125, 6.25. 12.5, 25, 50, 100, 200 and 400 orders
Fixed frequency span (asynchronous) : 0 to .1, .2, .5, 1, 2, 5, 10 and 20 kHz
Time domain averaging : 1, 2, 4, 8 or 16 averages, triggered by phase reference input
FFT resolution : 400, 800, 1600 and 3200 lines
FFT window : Rectangular or hanning
FFT averaging number : 1, 2, 4, 8 or 16 averages
FFT averaging mode : RMS peak hold, linear
FFT amplitude resolution : 12 bits
Scheduled sampling rate : 2.56 x frequency or order span
No. of samples in waveform sent to host : (2.56 x FFT resolution) samples
Scheduled minimum interval : 1 minute
Scheduled maximum interval : 59 hours
Orbit resolution (historic/scheduled) : 256 samples
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!