ASE2UDC920AE01 modular

[Product features]

Estimated lead time: 1-3 days

① Brand: ABB

② Model: ASE2UDC920AE01

③ Product category: module

④ Payment method: T/T, USD, Western Union

⑤ Freight: The freight in different regions shall be borne by the local freight forwarder.

⑥ Does it include tariffs? It does not include any taxes.

⑦ Packaging: use the Seller’s safe packaging.

PLC is generally used in small automatic control places, such as equipment control or a small amount of analog quantity control and interlocking, while large applications are generally DCS. Of course, this concept is not very accurate, but it is very intuitive. Traditionally, we call systems larger than 600 points DCS, and systems smaller than this scale PLC. The control system of our heat pump, QCS and horizontal products is generally called PLC.

Having said so much about the differences between PLC and DCS, we should realize that the development of PLC and DCS today is actually close to each other. Strictly speaking, today’s PLC and DCS can not be cut in one knife, and the concept between them has been blurred many times. Now, let’s discuss the similarities (similarities) between each other.

In terms of function.

PLC has the control function of analog quantity, and some PLC systems have even strong analog quantity processing capability, such as Siemens S7 400, AB’s Control Logix and Schneider’s Quantum system. DCS also has quite strong logic processing capability. For example, we have realized all possible process interlocks and equipment linkage start-stop on AC800F.

Category:
Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!

Description

It can be transported to all parts of the world.

(Excluding special circumstances, the area cannot be transported!)

If necessary, please contact customer service.

[Service contact information]

① Receive email replies within 24 hours (12 hours);

② Reply at any time, please add WeChat.

③ For shipment to countries outside Asia, please contact the seller. (part of the international region, free of freight)

[Product characteristics]

① Brand: ABB

② Model: ASE2UDC920AE01

③ Inventory quantity: 8

④ Color: new

⑤ Freight: according to different local freight forwarders, the freight in different regions shall prevail.

⑥ Include tariff or not: do not include any taxes

⑦ Packaging: use the Seller’s safe packaging

DCS usually uses a two-layer network structure. The first layer is a process-level network. Most DCS uses their own bus protocols, such as Profibus of Siemens and ABB, CAN bus of ABB, Modbus of Schneider, etc. These protocols are based on the standard serial port transmission protocol RS232 or RS485 protocol. The field IO module, especially the analog sampling data (machine code, 213/scan cycle) is very large, and there are many field interference factors, so the network standard with large data throughput and strong anti-interference ability should be adopted. The bus structure based on RS485 serial port asynchronous communication mode meets the requirements of field communication.

The sampling data of IO is converted into shaped data or real data by CPU and transmitted on the operation level network (layer 2 network). Therefore, the network standard of moderate data throughput, fast transmission speed and convenient connection can be adopted for the operation level network. At the same time, because the operation level network is generally arranged in the control room, the requirements for anti-interference are relatively low. Therefore, standard Ethernet is the best choice. TCP/IP protocol is a standard Ethernet protocol. Generally, we use a communication speed of 100Mbit/s.

The task of PLC system is relatively simple, so the amount of data to be transmitted is generally not too large, so the common PLC system is a layer of network structure. Either the process-level network and the operation-level network are combined, or the process-level network is simplified into the internal connection between modules. The PLC does not or rarely uses Ethernet.

ASE2UDC920AE01

ASE2UDC920AE01

530d3fe1a4daffa9d890 scaled ASE2UDC920AE01 modular

afd3e302f7bc10d35540 scaled ASE2UDC920AE01 modular

f9e1947a63e35b383d43 scaled ASE2UDC920AE01 modular

Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!