ICS TRIPLEX+T8312-4

¥9,999.00

  • Module Type: Safety I/O module
  • Input Type:
    • Digital inputs (typically 24V DC)
    • Configurable for different input types (e.g., contact closures, open/closed circuits)
    • Supports sinking or sourcing input devices
  • Output Type:
    • Digital outputs (24V DC)
    • Can drive relays, solenoids, or other actuators
  • Channels: 8 input channels, 4 output channels (varies depending on specific configuration)
Category:
Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!

Description

The ICS Triplex T8312-4 is a Safety I/O Module designed for use in critical process industries where safety, reliability, and fault tolerance are paramount. It is part of the Triplex series, which is widely known for providing high-performance, safety-critical automation solutions.

Product Name:

ICS Triplex T8312-4 Safety I/O Module

Product Description:

The T8312-4 is an advanced I/O module used within ICS Triplex safety systems. It serves as an interface between field devices (such as sensors, actuators, and switches) and the Triplex safety system. This module is designed for use in systems where high levels of safety, redundancy, and fault tolerance are necessary. It integrates seamlessly into Triplex systems, offering diagnostics, fault detection, and redundancy to ensure continuous and safe operations.

The T8312-4 module typically supports a range of digital I/O configurations and provides fault-tolerant operations in hazardous and mission-critical environments. The module is designed with built-in safety protocols and meets international standards for functional safety such as IEC 61508 and IEC 61511.

Product Parameters & Specifications:

  • Module Type: Safety I/O module
  • Input Type:
    • Digital inputs (typically 24V DC)
    • Configurable for different input types (e.g., contact closures, open/closed circuits)
    • Supports sinking or sourcing input devices
  • Output Type:
    • Digital outputs (24V DC)
    • Can drive relays, solenoids, or other actuators
  • Channels: 8 input channels, 4 output channels (varies depending on specific configuration)
  • Isolation: Optically isolated channels for safety and signal integrity
  • Redundancy: Built-in redundancy features to ensure high availability and fault tolerance
  • Communication Protocol: Utilizes standard Triplex communication protocols for seamless integration into the Triplex system
  • Safety Certification:
    • IEC 61508 (functional safety standard for electrical, electronic, and programmable electronic systems)
    • SIL 3 certification (Safety Integrity Level 3) ensuring high levels of safety
  • Diagnostic Features:
    • Continuous self-testing and monitoring
    • Automatic fault detection and reporting
    • Real-time diagnostics available via the Triplex system software
  • Power Supply: Typically powered by 24V DC or a similar low-voltage supply
  • Mounting: DIN rail or panel mounting
  • Environmental Rating: Suitable for harsh industrial environments (IP20, operating temperature range typically -40°C to +70°C)
  • Compatibility: Designed to work with ICS Triplex safety systems and controllers, ensuring integration with a broad range of industrial applications

Product Use:

The ICS Triplex T8312-4 module is used in safety-critical systems such as:

  • Process industries: Oil and gas, chemical, and petrochemical plants, where the safety and reliability of control systems are critical.
  • Power generation: Electrical power plants and substations where failure detection and redundant control mechanisms are necessary to avoid catastrophic consequences.
  • Manufacturing: For controlling and monitoring machinery, safety interlocks, and emergency shutdown systems in production facilities.
  • Transportation: Critical safety applications in rail or aviation systems, where failure could result in significant safety hazards.
  • Mining and hazardous environments: Ensuring worker safety and preventing accidents in environments where equipment failure could be dangerous.

The module is integrated into ICS Triplex safety systems, which are known for their ability to manage fault-tolerant, redundant control loops for safety applications. It can be used for tasks such as emergency shutdown (ESD), process monitoring, and safety instrumented systems (SIS).

Key Benefits:

  • High Safety Integrity: Meets high SIL 3 (Safety Integrity Level) requirements, ensuring that the system operates safely even under fault conditions.
  • Redundancy: Provides dual-channel configurations and diagnostic feedback to enhance system reliability.
  • Versatility: Supports a range of input/output types for various industrial applications.
  • Built-in Diagnostics: Continuous self-monitoring for early fault detection and quick system recovery.
  • Easy Integration: Part of the ICS Triplex family, it integrates seamlessly with other Triplex modules and systems.

79869679e8f6c86eeb90 ICS TRIPLEX+T8312-4

18da9b5e8007481c102f ICS TRIPLEX+T8312-4

ICS TRIPLEX+T8312-4

SGMPS-01ACA21 PLC
SGMPS-02ACA21
SGMAV-04ADA6C PLC
SGMAV-01ADA21
SGMAV-04ADA21 PLC
SGDM-1EADA PLC
SGDM-1AADA DCS
SGDM-75ADA DCS
NINT-68 PLC
SGMGH-09DCA6H-OY
SGMGH-09DCA6F-OY PLC
SGDM-60ADA PLC
SGDM-50ADA PLC
SGDM-40ADA PLC
SGDM-30ADA PLC
SGDM-20ADA PLC
SGDM-15ADA PLC
SGDM-05ADA PLC
SGDM-10ADA PLC
SGDM-08ADA PLC
Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!