BENTLY 3500/70M

¥9,000.00

Recip Velocity
Accuracy
Within ± 0.33% of full-scale
typical
± 1% maximum
Exclusive of filters
Velomitor
Additional accuracy degradation
occurs when full scale signal
levels are low:
Full Scale 0-0.5: ±3% typical
Full Scale 0-1.0: ±2% typical
Full Scale 0-2.0: ±1% typical
Frequency Response
Bias filter
-3 dB at 0.01 Hz
1-pole
Low-Pass
Not OK filter
-3 dB at 2400 Hz
1-pole
Low-Pass
Integration filter
-3 db at 0.34 Hz
1-pole
Low-Pass
RMS static values
-3 dB at 0.1 Hz
1-pole
Low-Pass
Peak static values
-3 dB at 0.3 Hz
1-pole
Low-Pass
1X & 2X Vector
Filter
Constant Q filter with bandwidth
= ±3% running speed
Q = 16.7
Filter Quality
High-pass
4-pole
80 dB per decade
24 dB per octave
Low-pass
2-pole
40 dB per decade
BENTLY 3500/70M
12 dB per octave

Category:
Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!

Description

Description
The 3500/70M Recip Impulse Velocity Monitor is a 4-channel
device used as part of the reciprocating compressor
solutions package to monitor compressor crankcase and
crosshead vibration. The monitor accepts input from seismic
transducers, conditions the signal to derive vibration
measurements, and compares the conditioned signals with
user-programmable alarms.
You can program each channel using the 3500 Rack
Configuration Software to perform the following functions:
l Impulse Acceleration
l Acceleration 2
l Recip Velocity
l Low Frequency Recip Velocity
The monitor channels are programmed in pairs and can
perform up to two of the aforementioned functions at a time.
For example, channels 1 and 2 can perform one function
while channels 3 and 4 perform another or the same
function.
The primary purpose of the 3500/70M Recip Impulse Velocity
Monitor is to provide the following:
l Machinery protection for reciprocating compressors by
continuously comparing monitored parameters
against configured alarm setpoints to drive alarms
l Essential reciprocating compressor machine
information for both operations and maintenance
personnel
Each channel, depending on configuration, typically
conditions its input signal to generate various parameters
called static values. You can configure alert setpoints for
each active static value and danger setpoints for any two of
the active static values.

5ebd619c033b44f2e9a5 1 scaled BENTLY 3500/70M

3711944e47ba81a758c1 1 scaled BENTLY 3500/70M

f7ef2737d81e1eae8313 1 scaled BENTLY 3500/70M

87549a9f48aeecb01b32 BENTLY 3500/70M
Impedance
Protection Each connector is short-circuit
protected.
Recorder Outputs
Recorder
+4 to +20 mA proportional to
monitor full-scale.
Selects one static data value
from each channel to be used for
that channel’s recorder value.
Voltage
compliance +12 Vdc maximum
Load resistance 600 Ω maximum
Resolution 0.3662 µA maximum
Update rate <100 millisecond Accuracy Within ±0.05 mA. ±0.14 mA over temperature range.

Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!