FOXBORO P0916DV

¥6,666.00

Brand: FOXBORO

Model: P0916DV

Ship to: Demander’s destination

Warranty period: 12 months

Delivery period: 1-3 days

Shipping weight: 5KG

Category:
Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!

Description

Best-selling brands:

ABB, GE Ventilation, A-B, Honeywell Honeywell, Kuka, Schneider Schneider, Bently Bentley, TRICONEX Invensys, Woodward of Xianglin, Foxboro, Foxboro, Westinghouse Electric, Motorola Motorcycle, Cormorgan KEBA Cole Morgan, Emerson Emerson, Sima Hema, and other major brands of distributed control system accessories, PLC system parts, robot system parts, large servo system parts. (The professional discontinued accessories are imported from the original factory with original packaging, and the customs declaration is provided, and the warranty is one year.)

Welcome to inquire more details

Condition: new original packaging

Warranty: All new or repaired parts have a 12-month warranty period

Payment: 100% telegraphic transfer of goods in stock before shipment

Availability: 24/7 service and free online quotation

All kinds of signal transmission lines connected to the PLC control system, in addition to transmitting effective signals, will always be invaded by external interference signals. There are two main ways of this interference: one is the power grid interference connected in series through the power supply of the transmitter or common signal instrument, which is often ignored; The second is that the signal line is interfered by the induction of space electromagnetic radiation, that is, the external induction interference on the signal line, which is very serious. The interference introduced by the signal will cause the I/O signal to work abnormally and the measurement accuracy will be greatly reduced, and in serious cases will cause damage to the components. For the system with poor isolation performance, it will also cause mutual interference between signals, cause common ground system bus backflow, and cause logic data change, misoperation and crash. The number of I/O module damage caused by signal introduction interference in PLC control system is quite serious, and there are many system failures caused by it.

Interference when grounding system is in disorder

Grounding is one of the effective means to improve the electromagnetic compatibility (EMC) of electronic equipment. Correct grounding can not only suppress the influence of electromagnetic interference, but also suppress the outward interference of equipment; On the contrary, the wrong grounding will introduce serious interference signals and make the PLC system unable to work normally. The ground wire of PLC control system includes system ground, shielding ground, AC ground and protection ground. The disturbance of the grounding system chaos to the PLC system is mainly caused by the uneven distribution of potential at each grounding point, and the existence of ground potential difference between different grounding points, which causes the ground loop current and affects the normal operation of the system. For example, the cable shielding layer must be grounded at one point. If both ends A and B of the cable shielding layer are grounded, there is a ground potential difference, and there is current flowing through the shielding layer. When abnormal conditions and lightning strikes occur, the ground wire current will be greater.

In addition, the shielding layer, the grounding wire and the earth may form a closed loop. Under the effect of changing magnetic field, there will be induced current in the shielding layer, which will interfere with the signal loop through the coupling between the shielding layer and the core wire. If the system grounding is confused with other grounding, the generated ground circulation may produce unequal potential distribution on the ground wire, affecting the normal operation of logic circuit and analog circuit in PLC. The logic voltage interference tolerance of PLC operation is low, and the distribution interference of logic ground potential easily affects the logic operation and data storage of PLC, resulting in data confusion, program flight or crash. The distribution of simulated ground potential will lead to the decline of measurement accuracy and cause serious distortion and misoperation of signal measurement and control.

“KOKUSAI KOMS-A2 technical parameters”

TRICONEX 2382 solution copy

IC698PSA100D technical article

IC693CPU364 module, in stock

KOMS-A2 CXP-544 technical parameters

FCM100ET solution copy

SM2337D technical parameters

CI570 module

FBM211 module

F7126 clamp

FX-316CE technical article

57C417 solution copy

FW239-DP parameter

5136-PFB-VME module, card

Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!