Description
Ordering number D136-001-007 D136-001-008 D136-001-001
Integrated interfaces
Ethernet 1 1
CAN 2 2
PROFIBUS-DP slave 1 –
Position transducer 2 2
Processor
Type PowerPC Processor, 32 Bit, RISC architecture with floating point unit
Flash EEPROM 4 MB
Data retention Typically 10 years
General technical data
Connection technique Plug-in terminal strips for screwing or clamping
Mounting NS 35/7.5 mounting rail according to EN 50022 (DIN rail)
Dimensions W x D x H 160 x 170 x 85.5 mm (6.30 x 6.69 x 3.36 in)
Attachment dimensions W = 149/154.5 mm (5.87/6.08 in)
Operating temperature range +5 to +55 °C (+41 to +131 °F)
Storage temperature range -25 to +70 °C (-13 to 158 °F)
Maximum mean temperature in operation for
24 hours
+50 °C (+122 °F)
Relative air humidity 10 to 95 % (non-condensing)
Maximum operation height 2,000 m (6,500 ft)
Maximum storage height 3,000 m (9,800 ft)
Maximum transport height 3,000 m (9,800 ft)
Protection class III
Degree of protection IP20
Standards
Operating equipment demands and
examinations
Insulation strength IEC 61131-2, test voltage 500 VDC
Power supply
Voltage supply of module electronics 24 VDC (18 to 36 V), SELV according to EN 60950-1
Current consumption of module electronics
Idling 0.5 A
Full load 2 A
Potential separation Separate potentials for:
• Module electronics
• 24-V supply
• Digital inputs/outputs
• Ethernet
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!