Description
D136-001-007
lnternal voltages
Generated via internal DC/DC converters
Behavior at voltage failure/cut-off of supply
Necessary data is permanently stored.If the supply voltage fails
voltage
(<18 V), buffer capacitors provide the necessary energy.
lnterfaces
Ethernet
10MBit/s with 8-pole RJ45 connector (10Base-T)
CAN
Two independent CAN interfaces,transmission rate adjustable from10kBit/s to 1 MBit/s:
. WideCAN: 2x D-Sub WCAN connectors on the front cover(connected internally 1:1)
LocalCAN: For communication with other Motion Controller viathe side Q-connectors or with the QEBUS module to furtherdevices
PROFIBUS-DP slave
12MBit/s
Serial port
2xEIA-232:
“MACS” on the front cover for communication with the MACSsoftware on a PC
. “SIO” on the front cover for free use in the application program
Extension bus (E-Bus)
Q-connectors on the right and left side of the module for connectingup to 7 additional modules.
Contains a serial bus (5 to 10MBit/s) and the LocalCAN bus.
Digital inputs/outputs
Type of digital inputs
Type 1 (current consuming) according to lEC61131-2
Number of digital inputs/outputs
8
Configuration
Individually configurable as input or output in the MACS software
Voltage supply
24Vpc(18 to 36 V),SELV according to EN 60950-1
Maximum current consumption of single output
0.5A
Protection
Sustained short-circuit
Yes
Thermal overload
Yes
Overvoltage
Up to ±36 v
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!