Description
Power supply
VM600Mk2/VM600 RPS6U rack power
supplies
: A VM600Mk2/VM600 ABE04x system rack can have either one or
two RPS6U rack power supplies installed, as follows:
• 1 × RPS6U power supply (330 W) supports the power requirements
for a full rack of modules (cards) in applications with operating
temperatures up to 50°C (122°F).
• 2 × RPS6U power supplies (330 W) – operating redundantly –
supports the power requirements for a full rack of modules (cards)
in applications with operating temperatures up to 50°C (122°F).
With this rack power supply redundancy, if one RPS6U fails, the
other will provide 100% of the rack’s power requirements so that the
rack will continue to operate.
Note: This is known as a redundant RPS6U rack power supply
configuration.
• 2 × RPS6U power supplies (330 W) – operating non-redundantly –
supports the power requirements for a full rack of modules (cards)
in applications with operating temperatures above 50°C (122°F),
where RPS6U output power derating is required.
Note: Even though two RPS6U rack power supplies are installed in
the rack, this is not a redundant RPS6U rack power supply
configuration.
Refer to the VM600Mk2/VM600 RPS6U rack power supplies
data sheet and a VM600Mk2/VM600 machinery protection system
(MPS) hardware manual for further information.
Power supply check relay
Nominal switching capacity
(resistive load)
: 4 A / 250 VAC, 3 A / 30 VDC
Maximum switching power
(resistive load)
: 1000 VA, 90 W
Maximum switching voltage : ±30 VRMS / ±42.4 VAC(PEAK) or 60 VDC
Maximum switching current : 4 AAC, 3 ADC
Environmental
According to IEC 60068-2 recommendations
Temperature
• Operating : 0 to 70°C (32 to 158°F)
• Storage : −40 to 85°C (−40 to 185°F)
Humidity : 0 to 90%, non-condensing
Vibration : 10 to 55 Hz, 0.35 mm peak, 6 hours in each direction
Shock : 15 g peak, 11 ms, half-sine pulse
Indoor use : Limited to indoor use only
Designation Ordering number (PNR)
ABE040 Different versions of the VM600Mk2 ABE040 system rack:
– Standard version 204-040-100-016
ABE040 Different versions of the VM600Mk2/VM600 ABE040 system rack:
– Standard version 204-040-100-015
– Varnished version, with a conformal coating for additional
environmental protection 204-040-100-015L
– Separate circuits version, in accordance with the IEC 60255-5 standard 204-040-100-115
– CCSAUS version, in accordance with the IEC 61010-1 standard 204-040-100-214
ABE042 Different versions of the VM600Mk2/VM600 ABE042 system rack:
– Version with mounting brackets positioned at the rear of the rack 204-042-100-01h
– Varnished version, with a conformal coating for additional
environmental protection 204-042-100-01hL
Different blank panel kits for the front of a VM600Mk2 ABE04x system rack:
– 1 × slot wide / 4 HP (TE) 200-505-011-012
– 3 × slots wide / 12 HP (TE) 200-505-018-012
Different blank panel kits for the rear of a VM600Mk2 ABE04x system rack:
– 1 × slot wide / 4 HP (TE) 200-505-011-012
Different blank panel kits for the front of a VM600 ABE04x system rack:
– 1 × slot wide / 4 HP (TE) 200-505-015-011
– 2 × slots wide / 8 HP (TE) 200-505-016-011
– 3 × slots wide / 12 HP (TE) 200-505-018-011
– 4 × slots wide / 16 HP (TE) 200-505-017-011
Different blank panel kits for the rear of a VM600 ABE04x system rack:
– 1 × slot wide / 4 HP (TE) 200-505-011-011
– 2 × slots wide / 8 HP (TE) 200-505-012-011
– 4 × slots wide / 16 HP (TE) 200-505-013-011
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!