Description
Manufacturer: REXROTH
Model: VM310
Shipping weight: 5Kg
Quantity: 1
Warranty period: from 1 year
Imported: Yes
Available for sale: worldwide
Grounding is one of the effective means to improve the electromagnetic compatibility (EMC) of electronic equipment. Correct grounding can not only suppress the influence of electromagnetic interference, but also suppress the outward interference of equipment; On the contrary, the wrong grounding will introduce serious interference signals and make the PLC system unable to work normally. The ground wire of PLC control system includes system ground, shielding ground, AC ground and protection ground. The disturbance of the grounding system chaos to the PLC system is mainly caused by the uneven distribution of potential at each grounding point, and the existence of ground potential difference between different grounding points, which causes the ground loop current and affects the normal operation of the system. For example, the cable shielding layer must be grounded at one point. If both ends A and B of the cable shielding layer are grounded, there is a ground potential difference, and there is current flowing through the shielding layer. When abnormal conditions and lightning strikes occur, the ground wire current will be greater.
In addition, the shielding layer, the grounding wire and the earth may form a closed loop. Under the effect of changing magnetic field, there will be induced current in the shielding layer, which will interfere with the signal loop through the coupling between the shielding layer and the core wire. If the system grounding is confused with other grounding, the generated ground circulation may produce unequal potential distribution on the ground wire, affecting the normal operation of logic circuit and analog circuit in PLC. The logic voltage interference tolerance of PLC operation is low, and the distribution interference of logic ground potential easily affects the logic operation and data storage of PLC, resulting in data confusion, program flight or crash. The distribution of simulated ground potential will lead to the decline of measurement accuracy and cause serious distortion and misoperation of signal measurement and control.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!