Description
TRICONEX 3721
MULTIPLEXER CONFIGURATION: Two independent 1×20
2-pole multiplexers. Banks can be connected together via
relay creating a single 1×40 multiplexer. Banks can be isolated from the backplane by relays. Card can be configured
for common side Ohms measurement via backplane relays.
Channel 41–42: Multiplex one of two 2-pole current signals
into DMM.
CONTACT CONFIGURATION: 2 pole form A.
CONNECTOR TYPE: Two 50 pin male D-shells. Removable
screw terminal option.
MAXIMUM SIGNAL LEVEL: Channels 1–40: 300V DC or RMS,
2A switched (3A carry), 60W, 125VA maximum. Channels
41–42: 60V DC or 30V RMS, 3A switched, 60W, 125VA maximum. Fused 3A, 250V RMS.
COMMON MODE VOLTAGE: Channels 1–40: 300V DC or RMS
between any terminal and chassis.
VOLT-HERTZ LIMIT: 8×107
.
CONTACT LIFE: >105
operations at maximum signal level. >108
operations no load.
1
Typical Scanning Speeds :
Switch Only 4: Sequential scanning, single channel, immediate trigger advance: >120 ch/s.
With Measurements Into Memory 5:
DCV (10V range) or 2W Ohms (1kW range): >110 ch/s
Thermocouple: >110 ch/s.
3- or 4-Wire RTD: >100 ch/s.
4-Wire Ohms (1kW range): >100 ch/s.
ACV (10V, 400Hz range) or ACI (1A, 400Hz range): >110 ch/s.
Dual
1×20 3
Single
1×40 2, 3
Channel Resistance
(end of contact life) <1.0 W <1.5 W
Contact Potential
(differential) <±1 µV <±3 µV
Offset Current <±250 pA <±250 pA
Isolation
Differential 109 W, 280 pF 109 W, 530 pF
Bank-Bank 1011 W, 60 pF —
Channel-channel 109 W, 50 pF 109 W, 50 pF
Common Mode 109 W, 180 pF 109 W, 480 pF
Crosstalk Channel-channel
300kHz <–60 dB <–60 dB
1MHz <–50 dB <–50 dB
20MHz: <–25 dB <–15 dB
Bandwidth 28 MHz 9 MHz
GENERAL
ACTUATION TIME: 4ms.
TEMPERATURE ACCURACY using Automatic CJC with
3721-ST accessory: 1°C for J, K, T, and E types (see
mainframe specification for details).
RELAY TYPE: Latching electromechanical.
RELAY DRIVE SCHEME: Direct.
INTERLOCK: Backplane relays disabled when interlock
connection is removed.
OPERATING ENVIRONMENT: Specified for 0° to 50°C.
Specified to 70% R.H. at 35°C.
STORAGE ENVIRONMENT: –25° to 65°C.
WEIGHT: 2.25 lbs.
SAFETY: Conforms to European Union Directive
73/23/EEC, EN61010-1.
EMC: Conforms to European Union Directive
2004/108/EC, EN61326-1.
Note s
1. Open detector enabled during thermocouple measurements. Minimum
signal level 10mV, 10µA.
2. 3706A mainframe with all DMM backplane relays disconnected.
Maximum two card backplane relays closed.
3. Connections made using 3721-ST accessory.
4. Scanning script local to 3706A mainframe, within same bank, and
break before make switching.
5. 3706A mainframe with autorange off, limits off, dmm.autozero=0,
dmm.autodelay=0, 4½ digits (NPLC=0.006), for ACV dmm.detectorbandwidth=300, for OHMs dmm.offsetcompensation=off, dmm.
opendetector=off. Scanning script local to mainframe, sequential scan
within same bank (2 pole) or card (4 pole), and break before make
switching
3500/15 127610-01 Correct use
FLB400 SCHENCK
8811-IO-DC MTL
FBM230 FOXBORO
How to repair 3500/42M 146449-02
SE04-10WA SINANO specification and model
8312 What about TRICONEX installation specifications
086339-001 ABB pattern analysis
K2-400 OF450/E KEBA
EPL10200-W with accessories EPZ-10203 CANPT010W3E
X410/50001 91001239 ABB promotional activities
EHDB280 ABB operation rules
YPQ110A ABB equipment common sense
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!